4th order Linkwitz-Riley filters, LP/HP 24dB per octave, made of two cascaded 2nd order Butterworth filters.
The sum of the Linkwitz-Riley HP and LP outputs, will result an all-pass filter at cutoff frequency and flat magnitude response.
Close to ideal for crossovers.
Example of a 2-way crossover at 500 Hz: send the same signal to two Linkwitz-Riley modules set to 500 Hz, one in LowPass and one in HighPass; the sum of the two outputs keeps a flat magnitude response.
Number of audio channels, asked when the module is created (1 = mono, 2 = stereo, up to 192). Each channel is processed independently and the module exposes one in N / out N pair per channel: with 1 channel only in 1 and out 1 exist.
Choose the number of channels actually carried by the signal. A mono source feeds a 1-channel module; duplicate the signal only where a stereo output is needed. To change the number of channels afterwards, recreate the module: the query is asked again and the connections are restored by name.
Bypasses the module processing when activated (ON).
Audio input flow(s).
Audio output flow(s).
Filter frequency.
Filter type:
Array of the channel numbers to filter, from 1 to the number of channels: for example 1,3 filters only the channels 1 and 3, the other channels are copied unchanged to their outputs. Empty or 0 (default): all channels are filtered. Reducing the list saves CPU.
Inlet visible only if the number of audio channels is > 2
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921
Edit All Pages