Script Overview

The Usine scripting language turns patches into programmable control surfaces, timing engines, and content generators. It extends Object Pascal with BrainModular-specific APIs so scripts can react to audio, MIDI, spatial data, and UI events across a workspace.

Script V2.0 introduces method-based access on parameters and Usine objects. If you are migrating from Script V1.x, review the compatibility notes to replace legacy helpers with their method equivalents.

Usine evaluates scripts at compile time, at the audio block rate, at the user interface refresh rate, whenever an inlet changes, and when the module is reset. The sections below detail how to structure a script, which APIs are available, and how those APIs map to BrainModular Usine features such as racks, the Master Synchro panel, MIDI Matrix modules, and XY Draw views.

procedure Callback(N: Integer);
begin
  if N = transpose then Trace('Semitones', transpose.asInteger);
end;

Writing and Compiling a Script

  1. Insert an Empty Script module in a patch.
  2. Double-click the module, or click show script editor in its properties tab, to open the script editor.
  3. Type the script, then click Compile (Ctrl+F9, Cmd+F9 on macOS) or Compile and Init (Ctrl+Shift+F9, Cmd+Shift+F9 on macOS). Compile keeps the current values of the inlets and outlets, Compile and Init resets them to their default values. After a successful compilation, Init runs and creates the inlets and outlets of the module.
  4. Read the result in the console at the bottom of the editor: compiled successfully, or the error with its position, for example Unknown declaration "x" at line 12, column 3, followed by Compiling failed. The editor places the cursor on the error, and the error is also reported in the Usine trace panel. As long as the script does not compile, the module shows placeholder terminals named -.
  5. Errors raised while the script runs (in Init, Process, a callback, ...) are reported in the Usine trace panel, one line per error: the procedure and the message with its line and column, then the module, its patch and its rack, for example script error : Process : Runtime error: "Index out of range" at line 12, column 5. When a procedure raises an error at every block, it writes one line per second at most, ending with (and N more errors since the last line). Use Trace to follow values at run time.

The text of a script may hold accents and symbols, in its strings and its comments: they are compiled as written. A script file is read as UTF-8 (as ANSI when it is not valid UTF-8) and saved as UTF-8 without BOM.

Script Architecture

Init

Init runs when the script module loads or recompiles. Create every inlet/outlet and initialize state because Usine clears globals between compile passes.

procedure Init;
begin
  noteIn := CreateParam('MIDI In', ptMidi, pioInput);
  noteOut := CreateParam('MIDI Out', ptMidi, pioOutput);

  transpose := CreateParam('Transpose', ptDataFader, pioInput);
  transpose.Min(-24);
  transpose.Max(24);
  transpose.Format('%.0f');

  tick := CreateParam('Tick', ptButton, pioInput);
  tick.CallbackMode(cbImmediate);
end;

This example maps to MIDI In/Out modules and a tick button that can drive an arpeggiator inside a patch.

In Init, DefaultValue also gives its value to a parameter of one value (a number, a gain, a MIDI note, a time code, a switch, a button, a list), at once and again when Init has returned, once Min and Max are known: call it anywhere in Init. Compile, which keeps the values, and a patch that loads still give the parameters their former values back. An Init that runs longer than its time limit is stopped: see Time Limits.

Destroy

Destroy runs before each new compilation of the script, with the former program, and when the module is deleted, once Process, ProcessThread and the callbacks running on other threads have stopped. Free dynamic structures created in Init.

Inlets and outlets are released automatically.

procedure Destroy;
begin
  noteNames.Free;
  SetLength(activeNotes, 0);
end;

Process

Process executes every audio block (typically 3 ms). Keep it deterministic, avoid GUI calls, and push results into outlets.

procedure Process;
var msg: TMIDI;
    i: Integer;
begin
  for i := 0 to noteIn.Length - 1 do
  begin
    msg := noteIn.asMidi(i);
    msg.data1 := msg.data1 + transpose.asInteger;
    noteOut.asMidi(i, msg);
  end;
  noteOut.Length(noteIn.Length);
end;

This transforms incoming MIDI data before it enters downstream MIDI Transformer or Sequencer modules.

ProcessThread

ProcessThread runs in its own worker thread every 20 ms. Use it for heavy calculations that should not block the audio chain or polling external devices.

procedure ProcessThread;
var i: Integer;
begin
  for i := 0 to pointsCount - 1 do
  begin
    cachedX[i] := GetObjectFloat(pointNames[i]);
    SetObjectFloat(targetNames[i], cachedX[i]);
  end;
end;

Avoid MIDI manipulation here; the worker thread is not sample accurate.

ProcessIDLE

ProcessIDLE runs on the UI refresh clock (25–50 ms). Trigger Usine messages, update colors, and perform housekeeping that should stay off the realtime thread like GUI stuffs.

procedure ProcessIDLE;
begin
  SendUsineMsg('panel', 'refresh', 'custom-display');
  ModuleColor($FF3298DB);
end;

Callback

Callback executes when an inlet changes. The integer argument identifies the parameter that triggered the event, making this the most efficient place to respond to user interaction. That allows an optimization over constant running Process procedure: the code will run only if input changed.

The Callback will scan the inputs from 0 to n and can trig a specific code when input change is detected.

So if results are supposed to be computed only when input changed, prefer the callback to the process procedure. However if things need computations at a different block time that input changed, still need the process procedure.

For example an input change can set to 1 a parameter in callback, but if wanna set this param back to 0 next block, (like a 'has chg' behavior) the code to set back to 0 will occur in Process Procedure, unless it's triggered by an input.

You can use either Callback or Process Procedure, or booth simultaneously according to your needs.

By default Callback is slow (cbMainThread mode): it is called on the main thread at messages rate, typically every 25 or 50ms depending on the setup refresh speed. Slow callbacks are suitable for GUI modification and dynamic patching. You can turn the Callback to fast for an inlet with the procedure : MyInlet.CallbackMode(cbImmediate): it is then called in the audio thread, just before the next call of Process.

For finer control, use CallbackMode to target a specific thread — for example cbImmediate for callback immediate (in audio thread), cbMainThread for general purpose callbacks, cbGraphic for UI repaints, or cbAsync for main-thread work queued after the cbMainThread callbacks (not background work: put heavy work in ProcessThread). cbVideo, cbRealTime and cbNetwork are not available to scripts: such a callback runs in cbMainThread mode, and a warning is traced. See Parameter Creation and Layout for the full list of modes.

procedure Callback(N: Integer);
begin
  case N of
    transpose:
      Trace('Transpose semitones', transpose.asInteger);
    tick:
      if activeNotesCount > 0 then PlayNextNote;
  end;
end;

OnReset

OnReset runs when the module is reset: with the reset button of the toolbar or the reset command of the context menu of its patch or of its rack, with the reset patch inlet of the usine-patch-settings module, or with the reset command of the module itself. A script inside a sub-patch is reset with it, once per voice of the polyphony. It runs on the main thread, like ProcessIDLE and the cbMainThread callbacks, so UI calls and dynamic patching are allowed.

procedure OnReset;
begin
  transpose.AsFloat(0);
  activeNotesCount := 0;
  SetLength(activeNotes, 0);
end;

Usine does not reset the parameters of a script module itself: set them and the state of the script back to their initial values in OnReset. The reset command applied to a single control of the control panel sets that control to its DefaultValue without calling OnReset. The reset reaches the module only while its can be reset option (properties tab) is ON, which is the default.

Threads

Procedure Where it runs
Init, Destroy, OnReset, ProcessIDLE main thread
Callback in cbMainThread (default), cbAsync or cbGraphic mode main thread
Process, Callback in cbImmediate mode audio thread; on the main thread when the engine is stopped and a click on a control runs the patch
ProcessThread a thread of its own
Callback for a SubscribeChunk notification real-time queue thread

In Process, ProcessThread, a cbImmediate callback and a chunk notification, never call SendUsineMsg, the dynamic patching functions (CreateModule, DeleteModule...), CreateParam, Sleep, Trace, a file function or a dialog: they block, or change the patch, on a thread that must not wait. SendUsineMsg and SendUsineMsgFile only run on the main thread: elsewhere they send nothing and trace a script error, as most dynamic patching functions do. When the engine is stopped, Process runs on the main thread and passes this test: an endless loop or a SendUsineMsg there is still a mistake.

A script cannot change what holds it while it runs. DeleteModule, and CreateModule or CreateFileModule when they replace a module, refuse the script itself and a sub-patch or a procedure that holds it, and the IML messages that would free the script are refused too. A script cannot compile itself either: setting its own compile, compile & init or script source inlet from the script is refused with a warning.

While a script compiles and its Init runs, its top patch pauses its processing, sub-patches and procedures included: a procedure of that patch called meanwhile skips its run, publishes nothing, and its call can start again. Before it compiles, a script waits up to 2 seconds for its runs on the other threads to end; when they do not, the compilation gives up, changes nothing and reports script busy.

Time Limits

A procedure of a script that runs too long is stopped, so that a loop that does not end cannot freeze Usine. The limits are settings of the expert tab of the setup:

Setting Procedures Default
script Init time limit Init 10000 ms
script main thread time limit the other procedures on the main thread: callbacks in cbMainThread, cbAsync or cbGraphic mode, ProcessIDLE, OnReset, Destroy, and Process when the engine is stopped 5000 ms
script other threads time limit Process, callbacks in cbImmediate mode, chunk notifications 1000 ms

0 turns a limit off, and ProcessThread has no limit. A run longer than its limit is stopped at its next loop turn, call or exit: a function of Usine that blocks, such as Sleep or a dialog, is not interrupted, and the stop comes when it returns. One error line is traced, and the procedure stays off until the script is compiled again. A stopped Init is an error of the script: the parameters it created before the stop exist, and the other procedures run. The time spent in a dialog opened by the script, and a pause of Usine in a debugger, are not counted.

These limits are not the watchdog of Usine, which keeps counting each error of a script. An AI assistant connected to the MCP server reads the longest run of each procedure since the last compilation, which helps to choose the limits.

Include Files

Scripts can share common code between several script modules with the {$include} compiler directive (alias {$i}). The directive inserts the content of another file at the point where it appears, before compilation.

{$include my-library.pas}

procedure Init;
begin
  // functions declared in my-library.pas are available here
end;

The file name is resolved like any other media file: absolute paths are used as is, and relative names are searched in the patch folder, the workspace folder and the package folders. If the file still cannot be found, Usine opens the file locator.

The MCP server refuses a script that holds an include directive (a directive in a comment, in a string or in a {$IFDEF} block that is off does not count): an AI assistant puts the code of the file in the script itself.

Use {$include_once my-library.pas} to include a file only the first time it is encountered, which avoids duplicate declarations when several included files include the same shared library themselves.

Reserved Identifiers

Script identifiers are case insensitive and share a single namespace with every built-in declaration. A variable or function cannot reuse the name of a built-in type, function or constant — the compiler stops with Duplicate declaration. Typical traps: pFloat/pSingle (the pointer types PFloat/PSingle exist), Log, Null, Platform, TParameter, Trace. When in doubt, prefix your variables (myFloat, paramGain, ...).

Control Flow

Loops (for, while, repeat) support break and continue. Both accept an optional depth: break(2) exits two nested loops at once. Exit leaves the current procedure or function immediately.

for i := 0 to count - 1 do
begin
  if values.asArray(i) < 0 then continue;   // skip this element
  for j := i + 1 to count - 1 do
    if values.asArray(j) = values.asArray(i) then
      break(2);                             // leaves both loops
end;

Operators and Language Extensions

Compound assignment operators

The C-style compound assignments are enabled by default:

x += 2;      // x := x + 2
x -= 1;      // x := x - 1
x *= 0.5;    // x := x * 0.5
x /= n;      // x := x / n

Operator overloading

Scripts can define operators on their own record types, which keeps vector, 3D or color math readable:

type TPoint2D = record
  x, y : single;
end;

operator + (a, b: TPoint2D): TPoint2D;
begin
  Result.x := a.x + b.x;
  Result.y := a.y + b.y;
end;

// later: p := p1 + p2;

Swap, Default, New, Dispose

Procedure Description
procedure Swap(var A, B); Exchange the contents of two variables of the same type
function Default(T): T; Return the zero/default value of a type (e.g. Default(TPoint2D))
procedure New(var P: pointer-to-record); Allocate a record for a typed pointer
procedure Dispose(var P: pointer-to-record); Free a record allocated with New

label / goto

Standard Pascal labels are supported: declare them in a label section, mark a statement with name: and jump with goto name;.

procedure Process;
label retry;
var attempts : integer;
begin
  attempts := 0;
retry:
  attempts += 1;
  if (not TryStep) and (attempts < 3) then
    goto retry;
end;

goto only jumps within the current procedure. In almost every case a loop with break/continue reads better — keep goto for rare bail-out patterns.

Compiler Hints

The compiler reports non-blocking hints in the script console at every compilation:

Hint Meaning
Variable "x" not used A global or local variable is declared but never used
Parameter "x" not used A procedure/function parameter is never referenced in the body
Parameter "x" not set A var/out parameter is never assigned in the body
Result not set A function never assigns its Result
Method "x" is deprecated / is deprecated "msg" A call to a function marked deprecated (e.g. TParameter.FastCallback — use CallbackMode)
Method "x" is not implemented A call to a function marked unimplemented
Method "x" is experimental A call to a function marked experimental

Scripts can mark their own functions with the same directives, after the header:

procedure OldHelper; deprecated 'use NewHelper instead';
begin
  ...
end;

Every call to OldHelper then reports the hint, which makes it easy to phase out old code shared between scripts.

Error Handling

Scripts support structured error handling with try..except..end and try..finally..end blocks. Both forms can be combined in a single try..except..finally..end statement.

except runs only when an error occurs in the protected block (for example a division by zero or an array access out of bounds). finally runs in every case, even when the protected block exits early — use it to release resources.

procedure Callback(N: Integer);
begin
  if N = trigger then
  try
    result.asFloat(numerator.asFloat / denominator.asFloat);
  except
    result.asFloat(0);  // fallback value on error
    Trace('calculation failed');
  end;
end;
procedure LoadList;
var list: TStringList;
begin
  list.Create;
  try
    list.LoadFromFile(fileName.asString);
    Trace(list.Count);
  finally
    list.Free;          // always executed, even on error
  end;
end;

Inside an except block, raise; re-raises the current error so it is reported by Usine as usual after the script has done its own cleanup.

Scripts can also raise their own errors with RaiseException, with a plain message or with a standard TIFException code (erCustomError, erOutOfRange, erDivideByZero, ...). ExceptionToString builds the corresponding message text.

if denominator.asFloat = 0 then
  RaiseException(erCustomError, 'denominator must not be zero');

The on E: Exception do typed clause is not supported: the except block catches every error, and the error message itself is not accessible from the script.

Execution Context Constants

BlocSize

BlocSize returns the number of samples in the current audio block. Use it to scale per-block accumulations or convert counts to milliseconds.

procedure Process;
begin
  rms := rms + sqr(input.asFloat) / BlocSize;
end;

BlocDuration

BlocDuration exposes the duration in milliseconds of the current audio block.

tempoLag := tempoLag + BlocDuration * 10.0;

RefreshSpeed

RefreshSpeed is the interval in milliseconds of the UI refresh loop. Tie slower automation to this cadence when running inside ProcessIDLE.

SampleRate

SampleRate holds the current audio sampling rate configured in the setup panel.

samplesPerBeat := Round((60 / hostTempo) * SampleRate);

Platform

Platform is a TPlatform enum that identifies the active operating system and hardware.

Type Description
plWindowsIntel Windows on x86/x64 processors.
plWindowsARM Windows on ARM processors.
plMacOSIntel macOS on Intel processors.
plMacOSARM macOS on Apple Silicon/ARM processors.
plLinuxIntel Linux on x86/x64 processors.
plLinuxARM Linux on ARM processors.
plIOSARM iOS/iPadOS on ARM processors.
plAndroidARM Android on ARM processors.
if Platform in [plWindowsIntel, plWindowsARM] then
  Trace('Running on Windows')
else
  Trace('Running on other platform');

Messaging and Diagnostics

Use these helpers to monitor script behavior and communicate with other BrainModular subsystems such as the Master Synchro panel, browser, or timeline.

Procedure Description
procedure Trace(S: string; Value: variant); Output a debug message combining a label and a value (variant type) to the Usine trace panel
procedure Trace(S: string); Output a text message to the Usine trace panel
procedure Trace(I: Integer); Output an integer value to the Usine trace panel
procedure Trace(F: Extended); Output a floating-point value to the Usine trace panel
procedure Trace(V: Variant); Output a variant value to the Usine trace panel
procedure Writeln(S: string); Output a text message to the Usine trace panel (same as Trace(S))
procedure Writeln(S1, S2: string); Output S1 followed by S2 on one line of the Usine trace panel
procedure Write(S: string); Same as Writeln(S): every call writes a line of its own

Trace

Trace is overloaded for strings, integers, floats, and variants. Each call writes one line to the Usine trace panel; the console of the script editor only shows the compilation messages. With a label, the label and the value are joined without a separator: end the label with one (Trace('tempo = ', hostTempo)).

Trace('Active voices: ', voiceCount.asInteger);
Trace('Tempo: ', hostTempo);
Trace('BlocSize');

Module Styling

ModuleColor

procedure ModuleColor(val: uint32);
procedure SetModuleColor(val: uint32);

Sets the module tint in the patch so custom scripts integrate visually with other modules. val is an $AARRGGBB color; the alpha byte is ignored and the color is always opaque. SetModuleColor is the same procedure under another name.

procedure Init;
begin
  ....
  ModuleColor($FF8E44AD);
end;

Transport Commands

Procedure Description
function GetTimecodePos: double; Gets the current Usine timecode position (in seconds or beats, depending on context)
procedure SetTimecodePos(pos: double); Sets the current Usine timecode position to the specified value

SetTimecodePos

procedure SetTimecodePos(pos: double);

Sets the current Usine timecode position to the specified value.

if jumpButton.asInteger = 1 then
  SetTimecodePos(musicTime);

GetTimecodePos

function GetTimecodePos: double;

Gets the current Usine timecode position.

  trace(GetTimecodePos);

more about scripts

version 7.0.250921