IML Messages

SendUsineMsg('SET_VAR', 'demo.tempo', '120');
SendUsineMsg('SET_VALUE', 'VOL1', 'gain', '-6');
Procedure Description
procedure SendUsineMsgFile(const FileName: string); Send a list of Usine messages stored in a text file
procedure SendUsineMsg(msg: string); Send a single Usine message without arguments
procedure SendUsineMsg(msg, arg1: string); Send a Usine message with one argument
procedure SendUsineMsg(msg, arg1, arg2: string); Send a Usine message with two arguments
procedure SendUsineMsg(msg, arg1, arg2, arg3: string); Send a Usine message with three arguments
procedure SendUsineMsg(msg, arg1, arg2, arg3, arg4: string); Send a Usine message with four arguments
procedure SendUsineMsg(msg, arg1, arg2, arg3, arg4, arg5: string); Send a Usine message with five arguments
function GetUsineVariableString(name: string): string; Retrieve the value of a Usine variable as a string; if the variable is not defined, the name itself is echoed back
function GetUsineVariableInteger(name: string): integer; Retrieve the value of a Usine variable as an integer
function GetUsineVariableFloat(name: string): single; Retrieve the value of a Usine variable as a floating-point number

SendUsineMsg and SendUsineMsgFile run only on the main thread: in Init, ProcessIDLE, OnReset, Destroy and the callbacks in cbMainThread (the default), cbAsync or cbGraphic mode. Called on another thread (Process while the engine runs, ProcessThread, a callback in cbImmediate mode, a chunk notification), they send nothing and trace a script error.

You can use them safely in the processIDLE procedure. In the callback procedure keep the parameter in the cbMainThread mode, the default (MyInlet.CallbackMode(cbMainThread);), so that the callback that contains the SendUsineMsg calls runs on the main thread.

Commands, target and limits

  • The commands are those of the templates engine: SET_VALUE, GET_VALUE, SET_VAR, SET_TARGET_PATCH, CREATE_MODULE, CREATE_LINK, DELETE_MODULE... With the overloads that take arguments, give the command name in upper case and with its underscores ('SET_VALUE'), then each argument as a string. SendUsineMsg(msg) alone reads a whole command line: its words are separated by spaces, the words without quotes are read in upper case, and a word in quotes ("My Patch") keeps its case and its spaces.
  • An unknown command does nothing and reports no error: check its spelling (SET_VALUE, never SET-VALUE). There is no command that starts the audio engine: set the on switch of a Usine Master Settings module of the patch, SendUsineMsg('SET_VALUE', 'MASTER', 'on', '1') for a module of user name MASTER.
  • A module is named by its user name (the case ignored), by a module variable, or by its order in the patch, and looked for in the target patch, then in its parent patch, then in its top patch, a user name in the sub-patches of each too. A path with dots (RackA.MyPatch.MyFader) is not read. A terminal is named by its caption, else by its index from 0.
  • Each SendUsineMsg call first makes the patch of the script (its sub-patch when it is in one) the target patch. A SET_TARGET_PATCH sent alone therefore lasts until the next call only: put it in a file sent with SendUsineMsgFile, where it holds for the next lines, or use the function SetTargetPatch for the dynamic patching functions. SET_TARGET_PATCH takes a rack index and a patch index (from 0), the caption of a patch of a rack of the current workspace, the user name of a sub-patch module, SENDER_PATCH (the target stays as it is) or PARENT_PATCH (the parent of the target).
  • A message that would free the script that sends it is refused, with a script error: DELETE_MODULE and RECREATE_MODULE of the script itself or of a sub-patch or a procedure that holds it; DELETE_PATCH, CLEAR_PATCH, LOAD_PATCH, RELOAD_PATCH, UNDO_PATCH and REDO_PATCH of a patch that holds it; CLEAR_RACK, DELETE_RACK and LOAD_RACK of its rack; CLEAR_WORKSPACE and LOAD_WORKSPACE when the script is in the current workspace. Since SendUsineMsg targets the patch of the script, CLEAR_PATCH, LOAD_PATCH, RELOAD_PATCH, UNDO_PATCH and REDO_PATCH sent with it are always refused: send them from a file, after a SET_TARGET_PATCH to another patch.
  • A value read by GET_VALUE is stored in a variable: read it with GetUsineVariableFloat or GetUsineVariableString, not GetUsineVariableInteger.
// example: the modules named here are modules of the patch of the script

// get the value of the module named Input1.asString, terminal Input2.asString,
// and store it in the internal variable 'THEPARAMVALUE'
SendUsineMsg('GET_VALUE', Input1.asString, Input2.asString, 'THEPARAMVALUE');

// set the terminal '1' of the module named 'THEMODULE' (the terminal captioned '1',
// else the second terminal) to the value 'THEPARAMVALUE' stored above
SendUsineMsg('SET_VALUE', 'THEMODULE', '1', 'THEPARAMVALUE');

// set the terminal Input2.asString of the module Input1.asString
// to the value of Input3.asFloat
SendUsineMsg('SET_VALUE', Input1.asString, Input2.asString, FloatToStr(Input3.asFloat));

SendUsineMsgFile

procedure SendUsineMsgFile(const FileName: string);

Send a list of Usine messages stored in a text file.

var
  BatchBtn   : TParameter;
  MessageFile: TParameter;

procedure Init;
begin
  BatchBtn := CreateParam('send file', ptButton, pioInput);
  BatchBtn.CallbackMode(cbMainThread);                    // run in the GUI/IDLE thread

  MessageFile := CreateParam('message file', ptTextField, pioInput);
  MessageFile.asString(IncludeTrailingPathDelimiter(GetApplicationPath) +
                       'iml-demo-messages.txt');
end;

procedure Callback(N: integer);
begin
  if N = BatchBtn then
    SendUsineMsgFile(MessageFile.asString);
end;

The file holds one command per line, read as SendUsineMsg(msg) reads its text; a target set by a line holds for the lines after it:

SET_TARGET_PATCH "Synth"
SET_VALUE VOL1 gain -6
SET_VALUE OSC1 frequency 220

SendUsineMsg (no arguments)

procedure SendUsineMsg(msg: string);

Send a single Usine message without arguments, or a whole command line: the words of the line are its command and its arguments, read in upper case unless they are in quotes.

var
  AddFaderBtn: TParameter;

procedure Init;
begin
  AddFaderBtn := CreateParam('add fader', ptButton, pioInput);
  AddFaderBtn.CallbackMode(cbMainThread);                 // keep IML off the audio thread
end;

procedure Callback(N: integer);
begin
  // a horizontal fader (class 3) named FADER1 at 100, 100 in the patch of the script
  if N = AddFaderBtn then
    SendUsineMsg('CREATE_MODULE fader1 3 100 100');
end;

SendUsineMsg (1 argument)

procedure SendUsineMsg(msg, arg1: string);

Send a Usine message with one argument.

var
  DeleteBtn : TParameter;
  ModuleName: TParameter;

procedure Init;
begin
  DeleteBtn := CreateParam('delete module', ptButton, pioInput);
  DeleteBtn.CallbackMode(cbMainThread);

  ModuleName := CreateParam('module name', ptTextField, pioInput);
  ModuleName.asString('FADER1');
end;

procedure Callback(N: integer);
begin
  // deletes the module of that user name in the patch of the script (never the script itself)
  if N = DeleteBtn then
    SendUsineMsg('DELETE_MODULE', ModuleName.asString);
end;

SendUsineMsg (2 arguments)

procedure SendUsineMsg(msg, arg1, arg2: string);

Send a Usine message with two arguments.

var
  StoreBtn : TParameter;
  TempoIn  : TParameter;

procedure Init;
begin
  StoreBtn := CreateParam('store tempo', ptButton, pioInput);
  StoreBtn.CallbackMode(cbMainThread);

  TempoIn := CreateParam('tempo', ptDataField, pioInput);
  TempoIn.Max(300);
end;

procedure Callback(N: integer);
begin
  if N = StoreBtn then
  begin
    // SET_VAR variable_name value: stores the value in the Usine variable 'demo.tempo'
    SendUsineMsg('SET_VAR', 'demo.tempo', IntToStr(TempoIn.asInteger));
    Trace('demo.tempo = ', GetUsineVariableInteger('demo.tempo'));
  end;
end;

SendUsineMsg (3 arguments)

procedure SendUsineMsg(msg, arg1, arg2, arg3: string);

Send a Usine message with three arguments.

var
  QueryBtn     : TParameter;
  ModulePath   : TParameter;
  TerminalName : TParameter;

procedure Init;
begin
  QueryBtn := CreateParam('query value', ptButton, pioInput);
  QueryBtn.CallbackMode(cbMainThread);

  ModulePath := CreateParam('module name', ptTextField, pioInput);
  ModulePath.asString('VOL1');                    // the user name of a module, not a path

  TerminalName := CreateParam('terminal name', ptTextField, pioInput);
  TerminalName.asString('gain');
end;

procedure Callback(N: integer);
begin
  if N = QueryBtn then
  begin
    // GET_VALUE module terminal variable: stores the value in the variable 'demo.variable'
    SendUsineMsg('GET_VALUE',
                 ModulePath.asString,
                 TerminalName.asString,
                 'demo.variable');
    Trace('current gain', GetUsineVariableFloat('demo.variable'));
  end;
end;

SendUsineMsg (4 arguments)

procedure SendUsineMsg(msg, arg1, arg2, arg3, arg4: string);

Send a Usine message with four arguments.

var
  ConnectBtn : TParameter;
  SourceModule: TParameter;
  SourcePin  : TParameter;
  TargetModule: TParameter;
  TargetPin  : TParameter;

procedure Init;
begin
  ConnectBtn := CreateParam('create connection', ptButton, pioInput);
  ConnectBtn.CallbackMode(cbMainThread);

  SourceModule := CreateParam('source module', ptTextField, pioInput);
  SourceModule.asString('OSC1');                  // user names of modules of the patch of the script

  SourcePin := CreateParam('source pin', ptTextField, pioInput);
  SourcePin.asString('out sin');

  TargetModule := CreateParam('target module', ptTextField, pioInput);
  TargetModule.asString('VOL1');

  TargetPin := CreateParam('target pin', ptTextField, pioInput);
  TargetPin.asString('in 1');
end;

procedure Callback(N: integer);
begin
  // CREATE_LINK source_module source_outlet target_module target_inlet
  if N = ConnectBtn then
    SendUsineMsg('CREATE_LINK',
                 SourceModule.asString,
                 SourcePin.asString,
                 TargetModule.asString,
                 TargetPin.asString);
end;

SendUsineMsg (5 arguments)

procedure SendUsineMsg(msg, arg1, arg2, arg3, arg4, arg5: string);

Send a Usine message with five arguments.

CREATE_MODULE takes the user name of the new module, the id of its class (see module's id), its left and its top, then the first query value of a class that asks one (the number of channels of an audio module, for example), or the file of a module made from a file, or -1: no value, and a class that asks one opens its query window. The module is created in the target patch, the patch of the script. The second query value, and the query values that follow a file, go in the command line of SendUsineMsg(msg): CREATE_MODULE name class left top value1 value2.

var
  SpawnBtn    : TParameter;
  ModuleID    : TParameter;
  ModuleName  : TParameter;
  PosX        : TParameter;
  PosY        : TParameter;

procedure Init;
begin
  SpawnBtn := CreateParam('create module', ptButton, pioInput);
  SpawnBtn.CallbackMode(cbMainThread);

  ModuleID := CreateParam('module id', ptTextField, pioInput);
  ModuleID.asString('3');                          // a horizontal fader (control-fader-horizontal)

  ModuleName := CreateParam('module name', ptTextField, pioInput);
  ModuleName.asString('AutoFader');

  PosX := CreateParam('pos x', ptTextField, pioInput);
  PosX.asString('120');

  PosY := CreateParam('pos y', ptTextField, pioInput);
  PosY.asString('40');
end;

procedure Callback(N: integer);
begin
  // CREATE_MODULE user_name class_id left top query_value
  if N = SpawnBtn then
    SendUsineMsg('CREATE_MODULE',
                 ModuleName.asString,
                 ModuleID.asString,
                 PosX.asString,
                 PosY.asString,
                 '-1');                            // -1: no query value (a fader asks none)
end;

GetUsineVariableString

function GetUsineVariableString(const name: string): string;

Retrieve the value of a Usine variable as a string.

var
  ReadStringBtn: TParameter;
  VariableName : TParameter;
  OutputText   : TParameter;

procedure Init;
begin
  ReadStringBtn := CreateParam('read string', ptButton, pioInput);
  ReadStringBtn.CallbackMode(cbMainThread);

  VariableName := CreateParam('variable name', ptTextField, pioInput);
  VariableName.asString('demo.string');

  OutputText := CreateParam('value out', ptTextField, pioOutput);
end;

procedure Callback(N: integer);
var
  value: string;
begin
  if N = ReadStringBtn then
  begin
    value := GetUsineVariableString(VariableName.asString);
    OutputText.asString(value);
  end;
end;

GetUsineVariableInteger

function GetUsineVariableInteger(const name: string): integer;

Retrieve the value of a Usine variable as an integer. A value stored by GET_VALUE is not an integer variable and gives -1: read it with GetUsineVariableFloat or GetUsineVariableString.

var
  ReadIntegerBtn: TParameter;
  IntegerVarName: TParameter;
  IntegerOutput : TParameter;

procedure Init;
begin
  ReadIntegerBtn := CreateParam('read integer', ptButton, pioInput);
  ReadIntegerBtn.CallbackMode(cbMainThread);

  IntegerVarName := CreateParam('variable name', ptTextField, pioInput);
  IntegerVarName.asString('demo.integer');

  IntegerOutput := CreateParam('value out', ptDataField, pioOutput);
end;

procedure Callback(N: integer);
begin
  if N = ReadIntegerBtn then
    IntegerOutput.asFloat(GetUsineVariableInteger(IntegerVarName.asString));
end;

GetUsineVariableFloat

function GetUsineVariableFloat(const name: string): single;

Retrieve the value of a Usine variable as a floating-point number.

var
  ReadFloatBtn: TParameter;
  FloatVarName: TParameter;
  FloatOutput : TParameter;

procedure Init;
begin
  ReadFloatBtn := CreateParam('read float', ptButton, pioInput);
  ReadFloatBtn.CallbackMode(cbMainThread);

  FloatVarName := CreateParam('variable name', ptTextField, pioInput);
  FloatVarName.asString('demo.float');

  FloatOutput := CreateParam('value out', ptDataField, pioOutput);
end;

procedure Callback(N: integer);
begin
  if N = ReadFloatBtn then
    FloatOutput.asFloat(GetUsineVariableFloat(FloatVarName.asString));
end;

more about scripts

version 7.0.250921

Edit All Pages