| Code | Description |
|---|---|
w001 - this item already exists |
Attempt to drop a device or a rack in rack-input-panel or rack-input-panel which already has been added. Duplicated items are not allowed. |
w002 - nothing to record |
Trying to record with the audio-recorder-panel but this one is empty, so there is nothing to record. Add at least one device or rack. |
w003 - clipboard empty |
Trying to use the paste command [cmd+v] but with an empty clipboard. |
w004 - edition disabled on this control |
Trying to [Double click] on a disabled fader or knob. Enable the edit enabled property. |
w005 - the object is locked |
The object is disabled or locked (edit enabled property OFF) and can't be modified. |
w007 - unable to undo |
Impossible to undo with the [cmd+z], probably because the undo history is empty. |
w008 - unable to redo |
Impossible to redo with the [shift+cmd+z], probably because the redo history is empty. |
w009 - nothing selected |
Attempt to use a delete command but nothing is selected, so there is nothing to delete. |
w010 - a Mixer already exists for this rack |
Attempt to drop a rack on the mixer-panel which already has been added. Duplicated items are not allowed. |
w011 - the control is not in a rack |
The control can't be located in a rack because it hasn't a parent rack. Typically because the control is in a device patch. |
w012 - the container or popup module doesn't exist |
The control can't be located in a popup or container because there is no popup or container in the patch. |
w013 - patch sharing is not activated in the setup |
Attempt to share a patch over the LAN without activating the share option in the setup. |
w014 - bind out of range |
The value assigned to a bind must be in the range [0..1]. Activate auto calibration or verify the range. |
w015 - OSC learn out of range |
The OSC value received and assigned with osc learn is not in the range [0..1]. Must be in this range when OSC mode is set to in [0..1]. |
w016 - this control can't be recorded |
Attempt to record an automation on a control which can't be recorded. Generally because they are read only or in the settings panel. |
w017 - not allowed to rename |
The current control can't be renamed with a [alt+click]. Generally because it is read only or in the settings panel. |
w018 - scan aborted |
The browser search (scan) has been canceled by the user, typically by pressing a key during the scan procedure. |
w019 - invalid path in FileLister module |
The path parameter of the file-lister is invalid. |
w020 - invalid filename |
The module load-workspace, load-rack, or load-patch has an invalid filename parameter and can't be processed. |
w021 - ID recreated |
After a Recreate ID's procedure, some IDs have changed and some presets can be lost. |
w022 - unable to convert script |
Conversion error during importation of an old version Script to the new Fast Script. |
w023 - artnet DMX is limited to 512 channels |
Attempt to send an ArtNet DMX value on a channel above 512. Values above this limit are ignored. |
w026 - no external editor defined in the setup |
You tried to edit an audio file but no external editor is defined in the setup. |
w030 - preset number doesn't exist |
You tried to store a preset number which doesn't exist; a new preset will be created. |
w031 - the grid is locked |
You can't move objects on the grid because it's locked. Unlock the grid. |
w032 - Video Device In module is not in a Video In Device patch |
Attempt to add a Video In device Module in a patch that is not a Device Patch. The module will not work. See video-tutorial. |
w033 - size clipboard empty or invalid |
Only in God mode — you tried to paste a control size but the clipboard is empty. |
w034 - no access to internet |
You have no access to the Internet. Addons, registering, and manuals will be inaccessible. |
w035 - feature unavailable in this version |
You tried to use a feature unavailable in this version of Usine. |
w036 - invalid device in MSC-create module |
You tried to create an MSC message with the MSC-create module but the output device is invalid. |
w037 - no enabled node selected |
You tried to change the settings of nodes in the pixel-mapper module but nothing is selected. |
w038 - reverse mode not allowed with samples 'on disk' |
It's impossible to play audio files in reverse when they are located 'on disk'. They must be 'in memory'. |
w039 - audio file re-sampled, it deteriorates performances |
The audio file sample rate differs from the sound card sample rate. The file is re-sampled on the fly, reducing performance. |
w040 - potential camera conflict, disable cameras in the video setup |
A Device-Input-Video module may conflict with an active camera. Disable cameras in /setup/video/. |
w041 - potential tempo conflict between connected computers |
Several computers are sending tempo information simultaneously. Disable send-tempo-and-synchro-info in /setup/network/. |
w042 - the video file can't be converted |
Usine can't convert the video file, probably due to special characters in the filename. |
w043 - the Modular module can't be in popup, top header, toolbox, IB only |
Modular inlets/outlets must be in the workspace, rack, or patch — not in a popup or window. |
w044 - Network is not activated in the setup |
You tried to send information on the network but it's not activated. Enable it in setup-panel-tab-network. |
w045 - No server available |
Something is wrong in the network setup — probably no output port available. |
w046 - The audio buffer size is too large to handle video or DMX properly |
The light or video engines need a buffer size less than 512 to work smoothly. Adjust in setup-panel-tab-audio. |
w047 - invalid time format in time control |
Invalid date format in the time control of the workspace-panel. Should be HH:MM:SS. |
w048 - the patch contains several info editor modules |
The patch contains multiple patch-info-editor modules — only one is allowed. |
w049 - invalid video record path |
The path defined in video-recorder is invalid. Usine will use the default system path. |
w101 - global array already exists |
You tried to create a global array that already exists in the workspace. Rename it. |
w150 - the number of racks is limited on this version |
Limited version restriction. |
w151 - the number of grid sections is limited on this version |
Limited version restriction. |
w152 - the number of patches is limited on this version |
Limited version restriction. |
w153 - This patch can't be edited on this version |
Limited version restriction — upgrade needed. |
w200 - please activate debug mode to enable fixed location |
You must be in debug mode to activate fixed location of scripts. |
wSDK100 - invalid color number |
A user module tried to get an Usine color that doesn't exist. |
| Code | Description |
|---|---|
e001 - unable to get addons list |
Usine can't access the server to get addons list — no Internet or server down. |
e002 - unable to create temp file |
Usine failed to create a temporary file in /temp. Directory write-protected, disk full, corrupted, or Dropbox conflict. |
e004 - unable to convert mp3 file |
Conversion process error when exporting to MP3 format. |
e005 - unable to read audio file |
Usine can't read the content of the audio file — file corrupted. |
e006 - empty file or not in memory |
You tried to save an empty audio file. |
e007 - unable to rename or copy the file |
Impossible to rename or copy the file: directory write-protected, disk full/corrupted, or sync conflict. |
e008 - bad audio file header |
The audio file is invalid or corrupted. |
e009 - out of memory |
No more memory available. On 32-bit, Usine shouldn’t exceed 3GB. |
e010 - audio driver not started, please choose it in the setup |
The audio driver hasn’t started or isn’t selected in the setup/audio. |
e011 - file not found |
The file you attempted to open wasn’t found. |
e012 - invalid inlets |
Usine tried to connect wires to unexpected in/outlets — usually compatibility issues with old patches. |
e013 - unable to paste at this position |
Usine can’t paste a grid item because the destination isn’t empty. |
e014 - unable to export the user module |
The patch contains invalid or deleted user modules. |
e015 - unable to load plugin |
Plugin can’t be loaded (wrong bitness, missing, or incompatible). |
e016 - a container module already exists in this patch |
Only one container module is allowed per patch. |
e017 - a popup module already exists in this patch |
Only one popup module is allowed per patch. |
e018 - this User Module isn't compatible with this version of Usine |
Incompatible or too old user module. |
e019 - send MIDI out, device not activated |
Attempt to send MIDI to a device not activated in setup/MIDI. |
e020 - send MIDI SysEx out, device not activated |
Attempt to send SysEx to a device not activated in setup/MIDI. |
e021 - invalid bar list |
Invalid bar list in master-synchro-panel. |
e022 - get index by order |
Internal message error — object not found. |
e023 - Usine busy |
Internal error — restart Usine. |
e024 - invalid format, not 16, 24 or 32 bits |
Unsupported audio format (only 16/24/32-bit supported). |
e025 - unable to open audio file |
Access conflict with another application. |
e026 - invalid MIDIfile format (old version) |
Attempt to open a very old MIDI file format. |
e027 - UDP Sendfile |
Error occurred during shared patch transfer. Usine will retry later. |
e028 - invalid UDP file transfer |
Shared patch transfer error — file corrupted. |
e029 - additional audio i/o module not allowed in this patch |
Patch can’t receive extra audio I/O modules (not a rack). |
e030 - queue overflow in Difference Array module |
Array too large to process in Difference Array module. |
e031 - inifile locked |
Internal error — restart Usine. |
e032 - in call Callback procedure |
Internal callback error in message loop. |
e033 - audio dropout |
Workspace took too long to process — plugin crash, heavy patch, or endless loop. |
e034 - artnet server not active |
Attempt to send ArtNet packets but ArtNet not activated in setup. |
e035 - unable to send Open DMX |
OpenDMX module not available on this system. |
e036 - invalid username, password or optional key |
Invalid credentials entered for Usine activation. |
e038 - invalid record directory in the setup |
Invalid Audio Recorder directory in setup. Recording aborted. |
e039 - unable to get battery information |
Battery Level module can’t retrieve data. |
e040 - error in update joystick procedure |
Unknown error in Joystick module. |
e041 - nothing recorded |
Attempt to email a file, but nothing recorded. |
e042 - invalid mail address |
Invalid email address for sending file. |
e043 - preset number doesn't exist |
Invalid preset number when recalling. |
e044 - can't connect to www.brainmodular.com |
Brainmodular site unreachable. |
e045 - password module already exists in the patch |
Only one password module allowed per patch. |
e047 - nothing recorded |
Main recorder panel is empty. |
e048 - invalid password |
The entered password is invalid. |
e049 - invalid MSC message |
The MSC message you tried to send is invalid. |
e050 - sorry, the setup has changed |
Old setup incompatible with this version. |
e051 - the old setup is in the same folder than the actual |
Can’t import setup from same folder as current Usine version. |
e052 - there was a problem when saving |
Unexpected issue during save (e.g. Dropbox conflict). Try again. |
e053 - invalid target-plot in pixel-mapper |
Invalid or inactive target plot in the pixel-mapper module. |
e053 - error downloading addon |
Error during addon list download — refresh in Addons Manager. |
e100 - global array not found |
Attempt to access a global array that doesn’t exist. |
e101 - CRC error in global array transfer |
Corrupted transfer of global array between connected computers. |
e201 - object not found |
Script attempted to get an object that wasn’t found. |
e202 - object hasn't value |
Script attempted to get the value of a non-value object (e.g., a Panel). |
version 7.0.250121