Filters multiple MIDI messages simultaneously and extracts their values.
All filters share the same message type (filter); each filter selects one data1 value (for example a CC number) and outputs the data2 value of the matching messages. The MIDI channel is not tested.
For example, with filter=control change, filter num 1=7 and filter num 2=10, a CC 7 of value 64 sets value out 1 to 0.504 (or 64 when force out range in 0..1 is off) and flashes pass 1.
Number of filters, asked when the module is created (1 to 32, 2 by default).
The module exposes one filter num N, value out N and pass N group per filter.
To change it afterwards, recreate the module: the query is asked again and the connections are restored by name.
Bypasses the module processing when activated (ON).
MIDI input flow(s).
Filtered output MIDI messages that match the filter type and one of the filter num values. When bypass is on, all messages go to this output.
Filtered output MIDI messages that do not match the filter type and filter num value.
Messages types (control change by default):
Data1 value (note or CC number) of the nth filter, from 0 to 127. There is one filter num N per filter; filter N is set to N by default.
Values of all the value out N outputs as an array.
Divides the output values by 127 to give a 0 to 1 range (on by default). When off, values are in the 0 to 127 range.
Data2 value (velocity, CC value) of the last message that passed the nth filter. There is one value out N per filter.
Pass triggers of all the filters as an array (1 when the filter passed a message in this block, 0 otherwise).
Light when the nth filter passes a message. There is one pass N per filter.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921