Receives a video flow from an NDI source of the network (NewTek NDI). It's only a prototype and some features are missing (like PTZ inputs).

Formerly Video NDI Camera. Its sources list outlet was called cameras list: saved patches keep their wires, but an object address that ends with .cameras-list must now end with .sources-list.
Enables the NDI Receive module.
List of available NDI sources on the network. Select the source you want to receive.
List of all available NDI sources as a comma-text.
Refreshes the list of available NDI sources.
Audio output flow(s).
The module has 4 audio outputs.
Size of the audio buffer in samples, from the Usine block size to 8191 (default 2048, logarithmic fader). Adjust to avoid audio glitches on slow networks.
For a better audio quality, it's recommended to use the same Usine audio samplerate than the NDI frame samplerate (generally 48kHz).
Video output flow(s).
Width in pixels of the video output frames.
Height in pixels of the video output frames.
Video output frame rate in frames per second.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.