Beat detector adapted to the detection of drum kicks.
The input is amplified by gain, filtered by a 2nd order low pass and followed by a peak envelope. A kick is detected when this envelope rises above 0.3 (about -10 dB); a new kick can only be detected once it has fallen below 0.15.
If kicks are missed, raise gain; if other sounds trigger, lower low pass frequency.
Audio input flow(s).
Volume applied to the input before analysis, range [-84..12] dB, default 0 dB.
Frequency of the low pass applied to the input sound to filter kicks, range [20..4000] Hz (log scale), default 500 Hz.
Release time of the detection envelope, range [5..100] ms, default 20 ms.
Sends a 1 value during one block when a beat is detected, 0 otherwise.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.