Laser Video to Laser

Transforms a video flow into a set of (X,Y,Z,COLOR) points that can be handled by an ILDA compatible device.

The conversion is made with a contour detection and a simplification of the image.

The laser output only works with the Helios Laser DAC, on Windows. See Laser Modules.

Settings

video in

Video input flow(s).

video out

Video output flow(s).

process time

Total time used for the calculation of the module.

on

Activates or deactivates the module.

laser xyz

Frames points coordinates a 3D array (X,Y,Z) points. Can be modified by 3D modules.

laser status

Array of status of the laser for each point: 0 for laser OFF and 1 for laser ON.

laser colors

Array of colors for each point.

threshold

Threshold of the contour detection. Pixels with a luminance below the threshold are set to black; those above are set to white, and the contours of the white zones are drawn.

size precision

Analysis resolution in pixels. Before the contour detection, the image is resized to size precision × size precision pixels, from 10 to 500 (default 200). Higher values give a more detailed drawing with more points; lower values simplify it.

dwell

Laser DWELL. Laser head inertia compensation. Number of "phantoms" points between lines.

A laser dwell is a period of time during which a laser beam is held in one spot, typically used in laser cutting or laser welding. During this time, the energy from the laser beam is concentrated on a small area, allowing for precise and efficient cutting or welding.

min line size

Minimum line size for the drawing, in pixels of the analysed image, from 0 to 100 (default 10): the contours of this length or shorter are not drawn.

frame color

Color of the output ILDA frame (laser colors), white by default.

Common Settings

info

show manual

Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.

For more details about information/help creation, see create-help-file.

description

Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).

preset ID

Read-only, not saved. Private ID used to store and recall the values of this control in presets.

recreate ID

Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.

Object Remote Address

absolute

Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.

local

Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.

user addr

Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.

See also

version 7.0.250921

Edit All Pages