Automatically scales an input data flow to a specified output range. Tracks the input minimum and maximum over a configurable time window and maps the input to the desired output range. Useful when the input range is unknown or varies over time, such as sensor data, gesture input, or external controllers.
output = minOut + (maxOut - minOut) * (input - trackedMin) / (trackedMax - trackedMin)
Bypasses the module processing when activated (ON).
Input Data flow(s).
Output Data flow(s).
Minimum value of the output range. Default is 0.
Maximum value of the output range. Default is 1.
Time window (in seconds) for tracking the input range. At each period, the tracked min/max is updated. Logarithmic scale from 1 to 200 seconds. Default is 20 seconds. Shorter values adapt faster but may be less stable.
Opens the web browser to display information or help about the selected object, if it exists.
For more details about information/help creation, see create-help-file.
Description of the module for internal help purposes only. The description is not displayed in the interface.
visible only in god mode, see setup-panel-tab-expert.
Current private ID for this control used to identify the object.
Current private preset ID for this control used for presets.
If you experience difficulties in Polyphonic mode, try to recreate new id(s) with this button.
Each Patch shared on the local network uses its own ID (identification number). If you experience issues of Patches that don't send information to the good target, this button will rebuild all these id's.
Absolute remote address. see objects-address.
Local to the current patch remote address. see objects-address.
User defined remote address. see objects-address.