Bus Set DMX

Sends a DATA flow to a bus designed for DMX processing. HTP (Highest Takes Precedence) is applied when multiple sources write to the same bus simultaneously.

Settings

value

Value of the bus.

name

Name of the bus.

set bus

Flow to send to the bus.

this inlet can be an array for multiple input values.

target

Target of the bus. Determines how the bus is accessible inside Usine.

  • global (all Usine): the bus is accessible in all the patches of the workspace.
  • rack only: the bus is accessible only in the current rack.
  • top parent patch: the bus is accessible in the top parent patch and all it's sub-patches.
  • current patch: the bus is accessible in the current patch and all its sub-patches.

on

Activates or deactivates the module.

send to shared computers

When ON, sends the values to all connected computers.

It will appear in the binds-panel of the connected computers.

Common Settings

info

show manual

Opens the web browser to display information or help about the selected object, if it exists.

For more details about information/help creation, see create-help-file.

description

Description of the module for internal help purposes only. The description is not displayed in the interface.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Current private ID for this control used to identify the object.

preset ID

Current private preset ID for this control used for presets.

recreate ID

If you experience difficulties in Polyphonic mode, try to recreate new id(s) with this button.

repair ID s

Each Patch shared on the local network uses its own ID (identification number). If you experience issues of Patches that don't send information to the good target, this button will rebuild all these id's.

Object Remote Address

absolute

Absolute remote address. see objects-address.

local

Local to the current patch remote address. see objects-address.

user addr

User defined remote address. see objects-address.

See also