Error & Warning Messages

Warnings

Code Description
w001 - this item already exists Attempt to drop a device or a rack in rack-input-panel or rack-input-panel which already has been added. Duplicated items are not allowed.
w002 - nothing to record Trying to record with the audio-recorder-panel but this one is empty, so there is nothing to record. Add at least one device or rack.
w003 - clipboard empty Trying to use the paste command [cmd+v] but with an empty clipboard.
w004 - edition disabled on this control Trying to [Double click] on a disabled fader or knob. Enable the edit enabled property.
w005 - the object is locked The object is disabled or locked (edit enabled property OFF) and can't be modified.
w007 - unable to undo Impossible to undo with the [cmd+z], probably because the undo history is empty.
w008 - unable to redo Impossible to redo with the [shift+cmd+z], probably because the redo history is empty.
w009 - nothing selected Attempt to use a delete command but nothing is selected, so there is nothing to delete.
w010 - a Mixer already exists for this rack Attempt to drop a rack on the mixer-panel which already has been added. Duplicated items are not allowed.
w011 - the control is not in a rack The control can't be located in a rack because it hasn't a parent rack. Typically because the control is in a device patch.
w012 - the container or popup module doesn't exist The control can't be located in a popup or container because there is no popup or container in the patch.
w013 - patch sharing is not activated in the setup Attempt to share a patch over the LAN without activating the share option in the setup.
w014 - bind out of range The value assigned to a bind must be in the range [0..1]. Activate auto calibration or verify the range.
w015 - OSC learn out of range The OSC value received and assigned with osc learn is not in the range [0..1]. Must be in this range when OSC mode is set to in [0..1].
w016 - this control can't be recorded Attempt to record an automation on a control which can't be recorded. Generally because they are read only or in the settings panel.
w017 - not allowed to rename The current control can't be renamed with a [alt+click]. Generally because it is read only or in the settings panel.
w018 - scan aborted The browser search (scan) has been canceled by the user, typically by pressing a key during the scan procedure.
w019 - invalid path in FileLister module The path parameter of the file-lister is invalid.
w020 - invalid filename The module load-workspace, load-rack, or load-patch has an invalid filename parameter and can't be processed.
w021 - ID recreated After a Recreate ID's procedure, some IDs have changed and some presets can be lost.
w022 - unable to convert script Conversion error during importation of an old version Script to the new Fast Script.
w023 - artnet DMX is limited to 512 channels Attempt to send an ArtNet DMX value on a channel above 512. Values above this limit are ignored.
w026 - no external editor defined in the setup You tried to edit an audio file but no external editor is defined in the setup.
w030 - preset number doesn't exist You tried to store a preset number which doesn't exist; a new preset will be created.
w031 - the grid is locked You can't move objects on the grid because it's locked. Unlock the grid.
w032 - Video Device In module is not in a Video In Device patch Attempt to add a Video In device Module in a patch that is not a Device Patch. The module will not work. See video-tutorial.
w033 - size clipboard empty or invalid Only in God mode — you tried to paste a control size but the clipboard is empty.
w034 - no access to internet You have no access to the Internet. Addons, registering, and manuals will be inaccessible.
w035 - feature unavailable in this version You tried to use a feature unavailable in this version of Usine.
w036 - invalid device in MSC-create module You tried to create an MSC message with the MSC-create module but the output device is invalid.
w037 - no enabled node selected You tried to change the settings of nodes in the pixel-mapper module but nothing is selected.
w038 - reverse mode not allowed with samples 'on disk' It's impossible to play audio files in reverse when they are located 'on disk'. They must be 'in memory'.
w039 - audio file re-sampled, it deteriorates performances The audio file sample rate differs from the sound card sample rate. The file is re-sampled on the fly, reducing performance.
w040 - potential camera conflict, disable cameras in the video setup A Device-Input-Video module may conflict with an active camera. Disable cameras in /setup/video/.
w041 - potential tempo conflict between connected computers Several computers are sending tempo information simultaneously. Disable send-tempo-and-synchro-info in /setup/network/.
w042 - the video file can't be converted Usine can't convert the video file, probably due to special characters in the filename.
w043 - the Modular module can't be in popup, top header, toolbox, IB only Modular inlets/outlets must be in the workspace, rack, or patch — not in a popup or window.
w044 - Network is not activated in the setup You tried to send information on the network but it's not activated. Enable it in setup-panel-tab-network.
w045 - No server available Something is wrong in the network setup — probably no output port available.
w046 - The audio buffer size is too large to handle video or DMX properly The light or video engines need a buffer size less than 512 to work smoothly. Adjust in setup-panel-tab-audio.
w047 - invalid time format in time control Invalid date format in the time control of the workspace-panel. Should be HH:MM:SS.
w048 - the patch contains several info editor modules The patch contains multiple patch-info-editor modules — only one is allowed.
w049 - invalid video record path The path defined in video-recorder is invalid. Usine will use the default system path.
w101 - global array already exists You tried to create a global array that already exists in the workspace. Rename it.
w150 - the number of racks is limited on this version Limited version restriction.
w151 - the number of grid sections is limited on this version Limited version restriction.
w152 - the number of patches is limited on this version Limited version restriction.
w153 - This patch can't be edited on this version Limited version restriction — upgrade needed.
w200 - please activate debug mode to enable fixed location You must be in debug mode to activate fixed location of scripts.
wSDK100 - invalid color number A user module tried to get an Usine color that doesn't exist.

Errors

Code Description
e001 - unable to get addons list Usine can't access the server to get addons list — no Internet or server down.
e002 - unable to create temp file Usine failed to create a temporary file in /temp. Directory write-protected, disk full, corrupted, or Dropbox conflict.
e004 - unable to convert mp3 file Conversion process error when exporting to MP3 format.
e005 - unable to read audio file Usine can't read the content of the audio file — file corrupted.
e006 - empty file or not in memory You tried to save an empty audio file.
e007 - unable to rename or copy the file Impossible to rename or copy the file: directory write-protected, disk full/corrupted, or sync conflict.
e008 - bad audio file header The audio file is invalid or corrupted.
e009 - out of memory No more memory available. On 32-bit, Usine shouldn’t exceed 3GB.
e010 - audio driver not started, please choose it in the setup The audio driver hasn’t started or isn’t selected in the setup/audio.
e011 - file not found The file you attempted to open wasn’t found.
e012 - invalid inlets Usine tried to connect wires to unexpected in/outlets — usually compatibility issues with old patches.
e013 - unable to paste at this position Usine can’t paste a grid item because the destination isn’t empty.
e014 - unable to export the user module The patch contains invalid or deleted user modules.
e015 - unable to load plugin Plugin can’t be loaded (wrong bitness, missing, or incompatible).
e016 - a container module already exists in this patch Only one container module is allowed per patch.
e017 - a popup module already exists in this patch Only one popup module is allowed per patch.
e018 - this User Module isn't compatible with this version of Usine Incompatible or too old user module.
e019 - send MIDI out, device not activated Attempt to send MIDI to a device not activated in setup/MIDI.
e020 - send MIDI SysEx out, device not activated Attempt to send SysEx to a device not activated in setup/MIDI.
e021 - invalid bar list Invalid bar list in master-synchro-panel.
e022 - get index by order Internal message error — object not found.
e023 - Usine busy Internal error — restart Usine.
e024 - invalid format, not 16, 24 or 32 bits Unsupported audio format (only 16/24/32-bit supported).
e025 - unable to open audio file Access conflict with another application.
e026 - invalid MIDIfile format (old version) Attempt to open a very old MIDI file format.
e027 - UDP Sendfile Error occurred during shared patch transfer. Usine will retry later.
e028 - invalid UDP file transfer Shared patch transfer error — file corrupted.
e029 - additional audio i/o module not allowed in this patch Patch can’t receive extra audio I/O modules (not a rack).
e030 - queue overflow in Difference Array module Array too large to process in Difference Array module.
e031 - inifile locked Internal error — restart Usine.
e032 - in call Callback procedure Internal callback error in message loop.
e033 - audio dropout Workspace took too long to process — plugin crash, heavy patch, or endless loop.
e034 - artnet server not active Attempt to send ArtNet packets but ArtNet not activated in setup.
e035 - unable to send Open DMX OpenDMX module not available on this system.
e036 - invalid username, password or optional key Invalid credentials entered for Usine activation.
e038 - invalid record directory in the setup Invalid Audio Recorder directory in setup. Recording aborted.
e039 - unable to get battery information Battery Level module can’t retrieve data.
e040 - error in update joystick procedure Unknown error in Joystick module.
e041 - nothing recorded Attempt to email a file, but nothing recorded.
e042 - invalid mail address Invalid email address for sending file.
e043 - preset number doesn't exist Invalid preset number when recalling.
e044 - can't connect to www.brainmodular.com Brainmodular site unreachable.
e045 - password module already exists in the patch Only one password module allowed per patch.
e047 - nothing recorded Main recorder panel is empty.
e048 - invalid password The entered password is invalid.
e049 - invalid MSC message The MSC message you tried to send is invalid.
e050 - sorry, the setup has changed Old setup incompatible with this version.
e051 - the old setup is in the same folder than the actual Can’t import setup from same folder as current Usine version.
e052 - there was a problem when saving Unexpected issue during save (e.g. Dropbox conflict). Try again.
e053 - invalid target-plot in pixel-mapper Invalid or inactive target plot in the pixel-mapper module.
e053 - error downloading addon Error during addon list download — refresh in Addons Manager.
e100 - global array not found Attempt to access a global array that doesn’t exist.
e101 - CRC error in global array transfer Corrupted transfer of global array between connected computers.
e201 - object not found Script attempted to get an object that wasn’t found.
e202 - object hasn't value Script attempted to get the value of a non-value object (e.g., a Panel).

See also

version 7.0.250121

Edit All Pages