Flow Toggle

Toggles the output value: alternates between the OFF value (default 0) and the ON value (default 1) each time the toggle inlet receives a 1 value.

Settings

out

Output flow(s).

toggle

Toggles the output each time it receives a 1 value:

  • If the out is equal to the ON value, it becomes the OFF value.
  • Otherwise, it becomes the ON value.

It reacts to the arrival of the 1 (trigger), not to a level: after each toggle the module puts the inlet back to 0, so an inlet held at 1 is seen as a new 1 at every cycle and keeps toggling, at most once per hold time. Drive it with a trigger, for example the output of a flow-from-0-to-1.

OFF value

Value sent when OFF.

ON value

Value sent when ON.

hold time

Minimum duration between two consecutive triggers.

Common Settings

info

show manual

Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.

For more details about information/help creation, see create-help-file.

description

Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).

preset ID

Read-only, not saved. Private ID used to store and recall the values of this control in presets.

recreate ID

Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.

Object Remote Address

absolute

Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.

local

Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.

user addr

Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.

See also

version 7.0.250921

Edit All Pages