N in - M out audio mixer. Each output is the sum of all audio inputs, each weighted by a coefficient taken from the mix values array. The number of inputs and the number of outputs are chosen when the module is created.
Can be connected with array-display module.
Number of inputs and number of outputs, asked when the module is created. The module exposes one numbered input per source (from in 0) and one output per destination; the mix values array holds one coefficient per input/output pair.
To change them afterwards, recreate the module: the query is asked again and the connections are restored by name.
Array of mixing coefficients from 0 to 1 (0: the input is not passed to the output, 1: the input is fully passed to the output).
The array must contain nb-inputs x nb-outputs values: one coefficient for every input/output pair. Inputs and outputs are numbered from 0 (in 0, in 1..., out 0, out 1...; with a single output it is called out). The array is organized output by output: the first nb-inputs values are the coefficients applied to in 0..in N-1 for out 0, the next nb-inputs values are the coefficients for out 1, and so on.
In other words, the coefficient applied to in i for out o is stored at index
o * nb-inputs + iof the array. If the array contains fewer values than nb-inputs x nb-outputs, the missing input/output pairs are simply not mixed. Coefficient changes are smoothed internally to avoid audio clicks.
With 4 inputs and 1 output:
mix values = [0.2, 0.5, 0.6, 0.1]
out = 0.2 * in 0 + 0.5 * in 1 + 0.6 * in 2 + 0.1 * in 3
With 3 inputs and 2 outputs (6 values: the first 3 feed out 0, the last 3 feed out 1):
mix values = [1, 0, 0.5, 0, 1, 0.5]
out 0 = 1 * in 0 + 0 * in 1 + 0.5 * in 2
out 1 = 0 * in 0 + 1 * in 1 + 0.5 * in 2
Audio input flow(s).
Audio output flow(s).
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921