Provides a replica of the master-light-panel.
See master-light-panel for more info.
Shows or hides the light plot panel.
Sends a "light panic" to all connected light devices.
One group of settings per plot, each caption followed by the plot number (universe num 1, universe num 2...). See the plot-panel for details.
DMX universe number of the plot, from 0 to 32767.
Master dimmer of the plot, from 0 to 1.
Resets the plot.
IP address where the ArtNet packets of the plot are sent.
When ON, the ArtNet packets are broadcast, restricted by the ArtNet broadcast mask.
Network mask used by the ArtNet broadcast.
When ON, the packets are sent at each cycle, even when the DMX values have not changed.
Determines how the sACN (streaming ACN, E1.31 DMX over IP) packets of the plot are sent on the network. Available for each plot of the plot-panel.
239.255.x.x, where x.x is the high and low byte of the universe number plus one (universe 0 = 239.255.0.1, universe 2 = 239.255.0.3, universe 512 = 239.255.2.1).Packets are sent only if send sACN is ON for the plot and the sACN protocol is activated in the setup-panel-tab-light.
IP address of the device that receives the sACN packets in unicast mode.
Network mask used in broadcast mode.
Same setting as ArtNet always send: when ON, the packets are sent at each cycle, even when the DMX values have not changed.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921
Edit All Pages