Usine contains a powerful OSC messages translator used to automatically convert incoming or outgoing OSC messages.
Available in the PLAYER, PRO and EXPERT versions
In the setup-panel-tab-network the OSC in translator file option allows to load a file which describes how the incoming messages have to be translated, and the OSC out translator file option a file for the outgoing messages. The same file can be loaded by both options.
The file is a text file with the extension .osc-translator.
:: example of OSC address conversion
[/position/*/x]
target=/usine/position/x/*
[/position/*/y]
target=/usine/position/y/*
In the example above the incoming OSC messages of the form /position/.../x will be translated into /usine/position/x/....
The * character is a joker. It means that it can take any value. For example input message /position/1/x will be translated into /usine/position/x/1 or /position/ball/x will be translated into /usine/position/x/ball.
By default the conversion is made in both direction for incoming and outgoing messages, when the file is loaded by both options. But you can specify the conversion direction
In the example above, the translation is made also for outgoing messages. So output messages of the form /usine/position/x/... will be translated into /position/.../x. For example output message /usine/position/x/1 will be translated into /position/1/x or /usine/position/x/ball will be translated into /position/ball/x.
mode=in (only for incoming messages)
mode=out (only for out going messages)
mode=in-out (default)
Example
:: example of different directions
[/get/position/*/x]
mode=in
target=/usine/position/x/*
[/set/position/*/x]
mode=out
target=/usine/position/x/*
The target is always the message that goes to or comes from Usine. So, in this example output messages /usine/position/x/*will be converted into /set/position/*/x.
You can specify the ranges of values if they have to be also converted.
min-source=-100, max-source=100 defines that the range of /position/*/x messages is in the interval [-100..100] and must be converted into min-target=0, max-target=1 so the interval [0..1].
:: range conversion
[/position/*/x]
min-source=-100
max-source=100
target=/usine/position/x/*
min-target=0
max-target=1
[/position/*/y]
min-source=-100
max-source=100
target=/usine/position/y/*
min-target=0
max-target=1
If the messages contains several type-tags you can specify for each value (up to 8 values, min-source1 to min-source8...), the ranges of the conversion as in the example below:
:: example of a 3 values message (type fff)
[/position/*/xyz]
min-source1=-100
max-source1=100
min-source2=-200
max-source2=200
min-source3=-50
max-source3=50
target=/usine/position/xyz/*
min-target1=0
max-target1=1
min-target2=0
max-target2=1
min-target3=0
max-target3=1
The first value (x) incoming value is in the range min-source1=-100, max-source1=100, the second value (y) is in the range min-source2=-200, max-source2=200 and the third value (z) is in the range min-source3=-50, max-source3=50. They will be converted in the range respectively min-target1=0, max-target1=1, min-target2=0, max-target2=1, etc.
You can specify a curve form for the translation : linear, logarithmic (log), exponential(expo), coefficient to dB (coefftodb), dB to coefficient (dbtocoeff).
curve=linear (default)
curve=log
curve=expo
curve=coefftodb
curve=dbtocoeff
Example
:: volume conversion
[/volume/]
min-source=0
max-source=1
target=/usine/volume/
min-target=-84
max-target=12
curve=log
As in the multiple range conversion above, you can specify different curves for each type-tag of the OSC messages.
:: example of a 2 values message (type ff)
[/volume-and-mute/]
min-source1=0
max-source1=1
min-source2=0
max-source2=1
target=/usine/volume-and-mute/
min-target1=-84
max-target1=12
min-target2=0
max-target2=1
curve1=log
curve2=linear
version 7.0.250921
Edit All Pages