Data Filter Smooth Attack Release

Smoother with independent attack and release times. The attack time controls how fast the output rises toward increasing input values, while the release time controls how fast it falls. Use it for asymmetric smoothing, envelope following, or any situation where rising and falling should behave differently.

The transitions are linear: after an input change, the output reaches the new value in attack time when rising and in release time when falling. For example, with attack time = 100 ms, a jump from 0 to 1 gives 0.5 after 50 ms and 1 after 100 ms.

Array elements are smoothed independently.

Settings

bypass

Bypasses the module processing when activated (ON).

  • OFF (0): Module processes normally
  • ON (1): Input passes directly to output without processing

in

Input Data flow(s).

this inlet can be an array for multiple input values.

out

Output Data flow(s).

attack time

Attack time in ms.

this inlet can be an array for multiple input values.

release time

Release time in ms.

this inlet can be an array for multiple input values.

Both times range from 0 to 100000 ms (logarithmic scale), default 100. A time of 0 gives an immediate change. When attack and release times are arrays, element N of the input uses element N of the times.

freeze

Freezes the current output value, ignoring further input changes. When freeze is turned off, the output resumes its transition toward the last input value.

no smooth on activation

If ON, the smooth is deactivated at the beginning of the patch calculation.

Common Settings

info

show manual

Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.

For more details about information/help creation, see create-help-file.

description

Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).

preset ID

Read-only, not saved. Private ID used to store and recall the values of this control in presets.

recreate ID

Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.

Object Remote Address

absolute

Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.

local

Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.

user addr

Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.

See also

version 7.0.250921

Edit All Pages