Hysteresis data filter (dead-zone). Only input changes greater than the hysteresis value are passed to the output. Small fluctuations are ignored. Use it to eliminate jitter from noisy controllers, MIDI knobs, or sensor data.
Bypasses the module processing when activated (ON).
Input Data flow(s).
Minimum change required for the output to update. For example, a value of 0.01 means changes smaller than 1% of the full range are ignored.
Output Data flow(s).
Opens the web browser to display information or help about the selected object, if it exists.
For more details about information/help creation, see create-help-file.
Description of the module for internal help purposes only. The description is not displayed in the interface.
visible only in god mode, see setup-panel-tab-expert.
Current private ID for this control used to identify the object.
Current private preset ID for this control used for presets.
If you experience difficulties in Polyphonic mode, try to recreate new id(s) with this button.
Each Patch shared on the local network uses its own ID (identification number). If you experience issues of Patches that don't send information to the good target, this button will rebuild all these id's.
Absolute remote address. see objects-address.
Local to the current patch remote address. see objects-address.
User defined remote address. see objects-address.
version 7.0.250121