Multi-channel reverberation module (Freeverb algorithm: parallel comb filters followed by allpass filters, per channel).
By default the module outputs the reverb only (wet level 0 dB, dry level at minimum): insert it on a send, or raise the dry level to use it as an insert.
Number of audio channels, chosen in a list when the module is created: mono, stereo, 4 channels, 8 channels, 16 channels, 32 channels, 64 channels, 5.1, 22.2 or 17.1 (the list index starts at 0: 0 = mono, 1 = stereo). The module exposes one in N / out N pair per channel.
Choose the number of channels actually carried by the signal. A mono source feeds a 1-channel module; duplicate the signal only where a stereo output is needed. To change it afterwards, recreate the module: the query is asked again and the connections are restored by name.
Audio input flow(s).
Audio output flow(s).
When On, freezes the content of the reverb's buffer indefinitely, to obtain an infinite reverb tail. OFF by default.
Controls the overall characteristics of virtual room size, from 0.1 to 100 % (default 95 %, exponential scale): larger values give longer tails.
This parameter controls the frequency absorption of the reverb tail, from 0 to 100 % (default 75 %).
Sets the width of the panning between channels, from 0 to 100 % (default 50 %).
The level of the reverberated signal, in dB (default 0 dB).
The level of the dry signal, in dB (default: minimum, no dry signal).
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921