Provides a replica of the master-synchro-panel of Usine. Gives access to the synchronization parameters.
Sends 1 value when the cycle starts.
Cycle length: Number of bars in the cycle.
Number of beat in the cycle.
Current position in the cycle.
Sends 1 value when the cycle position changes.
Cycle duration in milliseconds.
Bar Len: Number of beats in the bar.
Current position in the bar (beats).
Sends 1 value with the beat.
Bar duration in milliseconds.
Current eighth note position in the beat (1 or 2).
Sends 1 value when the eighth note position changes.
Current sixteenth note position in the beat (1, 2, 3, and 4).
Sends 1 value when the sixteenth note position changes.
Erases the proceeding adjustments by tap tempo in case of mistakes.
Multiplies the current tempo by 2.
Divides the current tempo by 2.
Set or get the tempo.
Switches ON or OFF the synchronization.
The PPQ position is generally used in plug-ins. Give PPQ the position within current cycle, in quarter notes
Restarts the synchronization from the beginning of the cycle.
Adjusts the tempo by successive taps.
Switches ON or OFF the timecode.
Restart the timecode from beginning.
Current timecode position value.
PPQ position from the beginning of the song, in quarter notes like cycle ppq. See above.
Current bar position.
Determines if parameters of this object are saved in the preset-panel.
Parameters of the this object can cross faded when you recall a preset in the grid.
Optional setting, does not appear on all objects.
List of bars with their time signature for the cycle. A cycle can be made of several bar with different time signatures.
for example:
4/4
4/4
3/4
Represents a cycle of two 4/4 bars and a 3/4 bar, so 11 beats. Allowed time signatures are x/1, x/2, x/4, x/8, x/16.
Moreover, you can define a precise tempo for each bar, for example
4/4=120
3/8=90
7/4=100
The first 4/4 bar will be at tempo=120, the second 3/8 at 90 and so on.
If this option is activated, the synchro restarts automatically from the beginning of the cycle when:
Perfect Synchro automatically changes the tempo to get bar length as a multiple of BLOC size. This give a much better synchro in loop recording.
Not recommended if your block size is greater than 128.
See setup-audio
Start/stops at the same time than the main Audio ON-OFF switch.
When activated, the tempo fader scale is larger (from 1 to 800 BPM instead of from 20 to 300 BPM).
Frame rate of the timecode in frames per second, from 10 to 60, 24 by default. It gives the frames field of the HH:MM:SS:FF timecode and the frame length of the LTC generator. An MTC generator changes it to an MTC rate (24, 25 and 30 are kept, another rate below 30 becomes 29.97, a rate above 30 becomes 30), and an MTC decoder with set main timecode ON sets it to the rate received. The frames are counted from the clock time: there is no drop-frame numbering.
Shows the ON-OFF switch of the synchro in the panel.
Shows the tempo in the panel.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921
Edit All Pages