Opens a serial port to communicate with a hardware device over a serial line: an Arduino or another microcontroller board, a USB-serial adapter, a Bluetooth serial device, etc.
The module sends text strings, byte arrays and MIDI/Firmata messages. It outputs the received bytes as an array: all of them, by blocks of a fixed size, or up to a delimiter byte.
Works on Windows, macOS and Linux.
This module replaces the former Serial Port user module. A patch saved with the user module opens with this module, with its values, settings and connections.
COM3, COM4, etc./dev/cu.usbmodem1411 or /dev/cu.usbserial-A600xxxx. The /dev/tty.* names also work./dev/ttyUSB0 for a USB adapter, /dev/ttyACM0 for an Arduino or another USB device of the CDC class, /dev/ttyS0 for a port of the motherboard (not shown in ports, type the name in port).The ports list shows the ports found on the computer.
On Linux, the user must belong to the dialout group to open a serial port: sudo usermod -a -G dialout $USER, then log out and log in again.
Name of the serial port. Changing it while the module is on opens the new port.
Serial ports found on the computer. Selecting a port sets port. The list is not saved with the patch: port is.
Searches the serial ports again, for example after plugging a device.
Transmission speed in bits per second, from 300 to 921600. It must match the speed of the device (for example Serial.begin(57600) in the Arduino code). A change is applied at once when the port is open.
Size of the blocks sent to rx data, from 0 to 128 bytes:
Byte value, from 1 to 255, that ends a message when rx buffer size is 0: for example 10 for a line feed (LF), 13 for a carriage return (CR). The delimiter is not part of rx data. 0 or -1: no delimiter.
Opens the port when on, closes it when off. A patch saved with the module on opens the port when it is loaded.
On while the port is open.
Text sent to the device each time it changes, as 8-bit characters (system code page on Windows, UTF-8 on macOS and Linux), without any line ending.
Bytes sent to the device each time the array changes, one byte per value.
Array values must be in the range 0-255.
MIDI messages sent to the device, each one as 3 bytes: the message, data 1 and data 2. The channel is not added to the message byte. This is the format of the Firmata protocol.
Drops the bytes received and not yet sent to rx data.
Bytes received, as an array of values from 0 to 255.
On when received bytes were lost because rx data did not read them fast enough, for example with a delimiter that never comes: rx data outputs at most one block or message per processing cycle.
protocol
For experts: the serial format. It must match the setting of the device.
parity
none, odd or even.
char size
Number of data bits, from 5 to 8.
stop bits
one, one point five or two. One point five is not available on macOS and Linux, where one stop bit is used.
trace
level
What the module writes in the trace panel. The errors are always written.
- none: nothing.
- info: the connections and the setting changes.
- debug: info, plus the number of bytes sent and received.
- verbose: debug, plus the bytes sent and received.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. When it is not empty, it is shown as the hint of the module (mouse over the module header in the patch) in place of the default module hint, even when the module hints are disabled.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250921